CO4031-FL CANopen HMI controller
The frenzel + berg electronic CO4031 CANopen-HMI-Controller supports all functions that are needed for realizing operating panels and display devices. Interfaces for alpha numeric LCD displays, matrix-keyboards, LED's and signalling devices are already implemented. The setup for CANopen node number, CAN baud rate and device configuration is done by external resistors or DIP switches.
system
- 16 Bit CPU
- supply voltage 5V DC
- temperature range -40 .. +105°C
- housing QFP64
interfaces
- display interface for up to 4x20 characters
- keyboard interface for matrix keyboard with 64 keys
- LED-interface matrix for 32 LED's
- signaling device interface digital (on/off)
CANopen
- CAN-Bus CAN V2.0b
- CAN-baud rate up to 1Mbit
- node number 1 .. 127
- CANopen Draft Standard DS301 V4.0 / DS401 V2.0
- CANopen diagnostic LEDs (output for LEDs)
- PDOs receive/transmit 1/2
- SDOs Server/Client 1/0
- PDO-Event Timer
- PDO-Inhibit Timer
- PDO-transmission mode event triggered, synchron,
asynchron, cyclic, anti cyclic, remote frame - variable PDO-identifier
- dynamic PDO-mapping
- emergency
- nodeguarding/lifeguarding/heartbeat
- object dictionary/configuration storable
- minimum boot up
- EDS-file
ordering information
article number | article name |
EZ00000.2011.01 | CO4031A-FL |